Golf GL L4-2.0L (AEG) (2001)
-
Change to display group 32 as follows:
-
Press -C- button.
-
Press buttons -0-, -3- and -2- to input display group number 32 (032) and press -Q- button to confirm input.
Indicated on display: (1-2 = display fields)
Read Measuring Value Block
->
1
2
-
Check oxygen sensor control learned value at idling (additive) in display field 1.
-
Check oxygen sensor control value at part load (multiplicative) in display field 2.