Golf GL L4-2.0L (AZG) (2001)
/Page-3008.png)
-
Connect VAG 1551 Scan Tool, select operating mode 1 "Rapid data transfer", switch on ignition and enter address word 17, "Instrument cluster".
-
Press -Q- button to confirm input.
-
Press -> button until "Select function" appears in display.
Indicated on display:
Rapid data transfer
HELP
Select function XX
-
Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer
Q
08 - Read Measuring Value Block
-
Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block
Input display group number XX
-
Press button -0- once and -2- twice to enter "display group 22".
-
Press -Q- button to confirm input.
-
Indicated on display
Read Measuring Value Block 22
->
1 1 1 2