If system is not fully dried, Airsept(R) will wash away with newly formed condensate.
Set Fresh air/heating controls as follows:
^
Temperature control knob to full hot
^
Fresh air blower to third speed (position 3)
^
Air distribution on bi-level (footwell and central A/C ducts)
^
A/C switched OFF
^
Recirculating flap switched OFF
Airsept(R) Application
-
Install AS2VW tool over studs for air intake in plenum (loosely secure with nuts if necessary).
-
Thoroughly shake bottle of Airsept(R) and install onto AS2VW tool.
-
Connect AS2VW applicator to air regulator Air regulator is pre-set at 58 Psi (4 bar) pressure.
Note:
Air supply must be 011 free.
Supply line pressure must be correct, too much or too little pressure will not provide the desired coverage.
-
Apply short bursts (approx. 3 seconds) of Airsept(R) using tool AS2VW until bottle is empty.
-
When bottle is empty, switch ignition OFF and let vehicle sit for approx. 30 minutes.
After 30 minute wait time:
-
Remove Airsept(R) bottle from tool, remove tool from vehicle, flush tool and bottle with clean water.
-
Fill Airsept(R) bottle with clean hot water and reinstall onto AS2VW tool, then apply air pressure until bottle is empty, flush tool with clean water
and discard Airsept(R) bottle.
-
Reinstall seal, air intake adapter, pollen filter (if equipped) and right side plenum cover.