volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heater Core > < A/C - No Cooling/Compressor Seized|Page 11053
Page 2
background image

2. Refrigerant lines on expansion valve
3. O-ring

-

13.7 mm; 2.5 mm 

4. Expansion valve

Removing: 
-

Evacuate refrigerant circuit using refrigerant recycling/recovery unit Kent-Moore ACR4 (or UL approved equivalent)

CAUTION:
-

Frostbite danger.

-

High pressure refrigerant may leak out if refrigerant circuit is not discharged.

-

Always evacuate refrigerant prior to opening refrigerant circuit. If refrigerant circuit is not opened within 10 minutes of evacuation,
pressure may form in refrigerant circuit due to evaporation. Evacuate refrigerant once more.
 

-

Remove bolts -1- and disconnect refrigerant lines -2- from expansion valve.

-

Remove bolts -8- and remove expansion valve -4-.

Installing: 
-

Install in reverse order of removal, noting the following:

-

Charge refrigerant circuit using refrigerant recycling/recovery unit Kent-Moore ACR4 (or UL approved equivalent)

-

Capacities

5. O-ring

-

14 mm; 1.82 mm 

-

Coat with refrigerant oil when installing

6. O-ring

-

10.8 mm; 1.82 mm 

-

Coat with refrigerant oil when installing

7. O-ring

-

9.5 mm; 2.5 mm 

8. Combination bolt

-

5 Nm 

Expansion valve, function 

-

The expansion valve restricts and controls refrigerant flow to the evaporator thus lowering refrigerant temperature and pressure.

Heater Core > < A/C - No Cooling/Compressor Seized|Page 11053