volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heated Oxygen Sensor (HO2S) G39 and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5439 > < Heated Oxygen Sensor (HO2S) G39 and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5437
Page 2
background image

Relay J757 terminal 2 for voltage.

Heated Oxygen Sensor

Engine Component Power Supply

(HO2S) G39 electrical

Relay J757 electrical harness 

harness connector

connector terminal

terminal 
4

2

Specified value: Battery voltage.

If the specification was not obtained:

-

Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the specification was obtained:

Checking Ground (GND) activation 
If the manufacturers test box is being used. Perform the following step.

-

Install the test box.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Motronic Engine Control Module (ECM) J623.

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) G39 electrical harness connector terminal 3 to the Motronic Engine Control Module
(ECM) J623 electrical harness connector T94 terminal 51 for an open circuit.

Heated Oxygen Sensor

Motronic Engine Control Module (ECM)

HO2S) G39 electrical harness

J623 electrical connector

connector terminal

T94 terminal or test box socket 

3

51

Specified value: 1.5 Ohms max.

If the specification was not obtained:

-

Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring and if the voltage supply was OK:

-

Replace the Motronic Engine Control Module (ECM) J623.

-

Install the engine cover with air filter.

Final procedures 
After the repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. See: Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 03: Interrogating Fault Memory
2. If necessary, erase the DTC memory. See: Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 04: Reset/Delete

Diagnostic Data

3. If the DTC memory was erased, generate readiness code.

-

End of diagnosis.

Heated Oxygen Sensor (HO2S) G39 and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5439 > < Heated Oxygen Sensor (HO2S) G39 and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 5437