volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Leak Detection Pump (LDP) V144, Checking|Page 5964 > < Leak Detection Pump (LDP) V144, Checking|Page 5962
Page 1
background image

Leak Detection Pump: Testing and Inspection
Leak Detection Pump (LDP) V144 Vacuum Supply, Checking

Leak Detection Pump (LDP) V144 Vacuum Supply, Checking 

Special tools, testers and auxiliary items required 

-

Turbocharger tester V.A.G 1397A

-

T-piece 251 201 346

-

Hose dia. 6 mm 

NOTE: 
-

Leak Detection Pump (LDP) V144 installation location

-

Rabbit/GTI: Under wheel housing liner in right rear wheel housing.

-

Eos: Behind right rear wheel.

Rabbit/GTI: 

-

Remove right rear wheel and wheel housing liner.

-

Remove vacuum line -1- from Leak Detection Pump (LDP) V144.

-

Connect Turbocharger Tester V.A.G 1397A with T-piece and dia. 6 mm hose between vacuum line -1- and Leak Detection Pump (LDP) V144
-2-.

Eos: 

-

Remove vacuum line -1- from Leak Detection Pump (LDP) V144.

-

Connect Turbocharger Tester V.A.G 1397A with T-piece and dia. 6 mm hose between vacuum line -1- and Leak Detection Pump (LDP) V144

Leak Detection Pump (LDP) V144, Checking|Page 5964 > < Leak Detection Pump (LDP) V144, Checking|Page 5962