volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Safety Precautions|Page 6640 > < Safety Precautions|Page 6638
Page 1
background image

Intercooler: Description and Operation

General Notes 

-

Charge air system must be properly sealed.

-

Always replace self-locking nuts.

-

Charge air hoses and pipes as well as their connections must be free of oil and grease before re-installation.

-

Do not assemble charge air hoses and pipes with lubricants containing oils, only coat with water (without additives) if necessary.

-

Note installation marks on hoses and components.

-

All hose connections for charge air system are secured by spring-type clamps or by connector couplings.

-

Install only approved clamps for securing hose connections.

-

Spring Type Clip Pliers or Hose clamp pliers are recommended for installing spring clamps.

-

For connector couplings, always note the following points:

-

Release connector coupling by pulling securing clip -arrow-.

-

Disconnect the hose and line without the assistance of tools.

-

When assembling, make sure the retaining tabs -A- are engaged securely.

Safety Precautions|Page 6640 > < Safety Precautions|Page 6638