Adapting the total distance travelled is only possible once and only in a positive (upwards) direction.

-

Adaptation can be interrupted with the "C" button of the VAG 1551

-

Correcting a false entry which has been confirmed is not possible. The instrument cluster must be exchanged for a new one.

-

Adaptation value must be entered in kilometers. For US models, adaptation value must be converted from miles to kilometers first (miles x 1.609 =
kilometers).

Adaptation, example

The malfunctioning instrument cluster has an odometer reading of 89627 km. This reading is transferred to the new instrument cluster as follows:

-

Connect scan tool VAG 1551, select operating mode 1 "Rapid data transfer", switch on ignition and enter address word 17 "instrument cluster".

-

Press -Q- button to confirm input.

-

Press -> button until "Select function"is displayed.

Indicated on display:

Rapid data transfer

HELP

Select function XX

-

Press button -1- twice to select "Login" function 11.

-

Press -Q- button to confirm input.

Indicated on display:

Rapid data transfer

Q

11 - Login procedure

-

Press -Q- button to confirm input.

Indicated on display:

Login procedure

Q

Enter code number XXXXX

-

Enter code number 13861.

Indicated on display:

Login procedure

Q

Enter code number 13861

"FAIL" appears in odometer if a false code or secret number is entered 3 times.

In this case terminal 30 (battery) must be disconnected and reconnected again and the Login procedure repeated using the correct code number.

-

Press -Q- button to confirm input.

Indicated on display:

Rapid data transfer

HELP

Select function XX

-

Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display:

Rapid data transfer

Q

10 - Adaptation

-

Press -Q- button to confirm input.

Indicated on display:

Adaptation
Enter channel number XX