volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Combination Valve, Checking|Page 3527 > < Combination Valve, Checking
Page 2
background image

Note:  Do not use any compressed air in the following test!

-

Remove intake hose to combination valve on top of air filter -arrow- and blow in with low pressure.
The combination valve must be closed.

-

Start hand pump.
The combination valve should open.

If the combination valve does not open:
-

Replace combination valve.

With Generic Scan Tool

Combination Valve, Checking

Recommended special tools and equipment

-

VAG1390 Hand Vacuum Pump

Test requirements

-

No leaks in vacuum lines or hose connections.

-

Vacuum hoses not clogged or kinked

-

Pressure hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked

Test sequence

Vehicles with engine code AFP

NOTE:  Do not use pressurized air for the following test.

-

Remove front noise insulation.

-

Disconnect vacuum hose from combination valve at Secondary Air Injection (AIR) Solenoid Valve -N112-, item 5.

-

Connect hand vacuum pump (VAG1390) at vacuum connection to combination valve.

Combination Valve, Checking|Page 3527 > < Combination Valve, Checking