GTI V6-2.8L (BDF) (2002)
-
Carry out a road test to remove possible residue on Oxygen Sensor (O2S) and repeat check.
Observe the valid safety precautions when carrying out a road test. Refer to "Fuel Delivery and Air Induction/Service Precautions".
See: Fuel Delivery and Air Induction/Service Precautions/Technician Safety Information
If the display does not indicate as described again:
-
Check Oxygen Sensor (O2S) and Oxygen Sensor control after Three Way Catalytic Converter (TWC).
See:
With Generic Scan Tool
Oxygen Sensor And Oxygen Sensor Control Behind Three Way Catalytic Converter (TWC), Checking
NOTE:
-
Vehicle must be raised before connector for oxygen sensor is accessible.
-
When servicing terminals 3 and 4 in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.
Recommended special tools and equipment
-
VAG1526 multimeter or VAG1715 multimeter
-
VAG1594 connector test kit
-
Wiring diagram
Test requirements
-
The respective fuses of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130- must be OK.
-
Battery voltage must be at least 11.5 volts.
-
All electrical consumers like, for example, lights and rear window heating must be switched off.
-
Parking brake must be engaged or else daylight driving lights will be switched on.
-
For vehicles with automatic transmission, selector lever must be in position -P- or -N-.
-
If vehicle is equipped with an A/C system, it must be switched off.
-
Ground (GND) connections between engine and chassis must be OK.
-
Exhaust system must be properly sealed between catalytic converter and cylinder head.
-
Coolant temperature must be at least 80 degree C, Diagnostic mode 1: Check measuring values; PID 5, Coolant temperature.
See: Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 1: Check Measured Values
-
Oxygen sensor heater for oxygen sensor behind catalytic converter must be OK.
See: Testing and Inspection/Component Tests and General Diagnostics/Oxygen Sensor Heater For O2 Sensor After TWC, Checking
Function test
-
Select the output of oxygen sensor signals and check whether the specified values are being reached, Diagnostic mode 5: Check output of oxygen
sensor signals.
See: Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals
If specified values are obtained:
-
End diagnosis and switch ignition off.
If specified values are not obtained:
-
End diagnosis and let engine continue to run at idle.
-
Check primary voltage.
Checking primary voltage