volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Combination Valve, Checking|Page 3241 > < Combination Valve, Checking|Page 3239
Page 2
background image

-

Connect hand vacuum pump VAG 1390 to vacuum hose from combi-valve -arrow-.

-

Disconnect pressure hose to combi-valve at coupling -arrow- and blow in using light pressure.
Combi-valve must be closed.

-

Operate hand vacuum pump.
Combi-valve must open.

-

When the combi-valve does not open or is continuously open

-

Replace combi-valve.

With Generic Scan Tool

Secondary Air Injection (AIR) Valve, Checking

Solenoid valve is closed when no voltage is present.

Recommended special tools and equipment

-

VAG1526 multimeter or VAG1715 multimeter

-

VAG1594 connector test kit

-

Wiring diagram

Test requirements

-

The respective fuses of Secondary Air Injection (AIR) Solenoid Valve -N112- must be OK.

-

Ignition switched off.

Test sequence

Combination Valve, Checking|Page 3241 > < Combination Valve, Checking|Page 3239