Intake Air Temperature Sensor: Testing and Inspection
With Manufacturer's Scan Tool

Intake Air Temperature (IAT) Sensor - G42-, Checking

NOTE:  The Intake Air Temperature (IAT) sensor -G42- is a component part of the Mass Air Flow (MAF) sensor -G70- and cannot be replaced
individually.

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

-

VAG 1551 Scan tool (or VAG 1552) with VAG 1551/3 adapter cable

NOTE:  All functions which could previously be performed with VAG 1551/1552 can also be performed with the VAS 5051.

-

VAG 1526 Hand multimeter or VAG 1715 multimeter

-

VAG 1594 Adapter set

-

VAG 1598/31 test box

-

VAS 5024 Assembly tool for spring-type clips

-

Electrical Wiring Diagrams

-

Chilling spray (commercially available)

Test prerequisites

-

Selector lever must be in position "P" or "N" on vehicles with an automatic transmission.

Test sequence

NOTE:  Only gold plated terminals may be used to service the terminals in the Intake Air Temperature (IAT) sensor.

-

Connect VAG 1551 Scan tool (or VAG 1552). Then switch ignition on and select Motronic Engine Control Module (ECM) -J220- with the
"Address word" 01. ((VAG 1551 and Motronic Engine Control Module (ECM) -J220-, connecting and selecting).  

See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool
Connecting/With Manufacturer's Scan Tool/Connecting VAG 1551 Scan Tool

Indicated on display:

Rapid data transfer 

HELP

Select function XX

-

Press buttons -0- and -8- for function "Read measured value (data) block" and confirm entry with -Q- button.

Indicated on display:

Read measured value block
Input display group number XXX

-

Press buttons -0-, -0- and -4- for "Display group number 4" and confirm entry with -Q- button.

Indicated on display: (1 to 4 = display zones)

Read measured value block 4 

->

4

-

Read intake air temperature value in display zone 4.
Specification: approx. ambient temperature