Jetta L5-2.5L (BGP) (2006)
If the specification was not obtained:
-
Replace the Heated Oxygen Sensor (HO2S) G39.
If the specification is obtained:
Checking voltage supply
-
Crank the engine.
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) G39 electrical harness connector terminal 4 to Ground (GND) for voltage.
Heated Oxygen Sensor (O2S)
Measure to
G39 electrical harness
terminal connector
4
Ground (GND)
-
Switch the ignition off.
Specified value: Battery voltage.
If the specification was not obtained:
-
Check the Heated Oxygen Sensor (HO2S) G39 electrical harness connector terminal 4 to the Fuel Pump (FP) Relay J17 socket 2/87 for an open
circuit, a short circuit to each other, or Ground (GND).
-
Check the electrical harness connector for damage, corrosion, loose or broken terminals.
-
If necessary, repair the faulty wiring connection.
If the specification was obtained:
Checking Ground (GND) activation
If the manufacturers test box is being used. Perform the following step.
-
Install the Adapter Cable (121 -pin) VAG1598/31.
If the manufacturers test box is not being used. Perform the following step.
-
Remove the Motronic Engine Control Module (ECM) J220.
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) G39 electrical harness connector terminal 3 to the Motronic Engine Control Module
(ECM) J220 electrical harness connector T121 terminal 5 for resistance.
Heated Oxygen Sensor (HO2S)
Motronic Engine Control Module