Leak Detection Pump: Testing and Inspection
Fuel Injection and Ignition - Fuel Supply

EVAP Leak Detection Pump Vacuum Supply, Checking (BGP,BGQ,CBTA,CBUA)

Special tools, testers and auxiliary items required

-

Turbocharger tester V. A. G 1397A

-

T-piece 251 201 346

-

Hose dia. 6 mm

NOTE:  Leak Detection Pump (LDP) V144 component location: Under wheel housing liner in right rear wheel housing.

-

Remove right rear wheel and wheel housing liner.

-

Remove vacuum line - 1 - from Leak Detection Pump (LDP) V144.

-

Connect Turbocharger Tester V.A.G 1397A with T-piece and 6 mm dia. hose between vacuum line - 1 - and Leak Detection Pump (LDP) V144 -
2 -.

-

Switch on measuring range 1 (absolute pressure measurement).

-

Connect vehicle tester and start engine.

-

Select Guided Functions operating mode on vehicle diagnostic tester.

-

Select "Check tank ventilation system for leaks" Guided Function. Activate test.

-

While test is running, observe display on Turbocharger Tester V.A.G 1397A.
-

The pressure must pulsate and must not rise above 0.700 bar (absolute pressure) during the test.

-

If pressure rises above 0.700 bar during the test, the vacuum supply is too low. Check vacuum line to intake manifold for kinks or blockages.