Jetta L5-2.5L (CBTA) (2008)
Leak Detection Pump: Testing and Inspection
Fuel Injection and Ignition - Fuel Supply
EVAP Leak Detection Pump Vacuum Supply, Checking (BGP,BGQ,CBTA,CBUA)
Special tools, testers and auxiliary items required
-
Turbocharger tester V. A. G 1397A
-
T-piece 251 201 346
-
Hose dia. 6 mm
NOTE: Leak Detection Pump (LDP) V144 component location: Under wheel housing liner in right rear wheel housing.
-
Remove right rear wheel and wheel housing liner.
-
Remove vacuum line - 1 - from Leak Detection Pump (LDP) V144.
-
Connect Turbocharger Tester V.A.G 1397A with T-piece and 6 mm dia. hose between vacuum line - 1 - and Leak Detection Pump (LDP) V144 -
2 -.
-
Switch on measuring range 1 (absolute pressure measurement).
-
Connect vehicle tester and start engine.
-
Select Guided Functions operating mode on vehicle diagnostic tester.
-
Select "Check tank ventilation system for leaks" Guided Function. Activate test.
-
While test is running, observe display on Turbocharger Tester V.A.G 1397A.
-
The pressure must pulsate and must not rise above 0.700 bar (absolute pressure) during the test.
-
If pressure rises above 0.700 bar during the test, the vacuum supply is too low. Check vacuum line to intake manifold for kinks or blockages.