volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor (O2S) Before Catalytic Converter|Page 2575 > < Oxygen Sensor (O2S) Before Catalytic Converter|Page 2573
Page 9
background image

Input display group number XXX

-

Press keys 0, 3 and 4 for "Display group number 34" and confirm entry with Q key.

Indicated on display: (1...4 = Display zones)

System in basic setting 34

->

1

2

3

4

-

Depress brake pedal and hold.

-

Press accelerator pedal to wide open throttle position.
The engine speed is increased by the control module to 1800...2200 rpm.

-

Maintain engine speed at 1800...2200 rpm until display in display zone 4 jumps from "Test OFF" to "Test ON". Catalyst temperature in display
zone 2 must be 350...500 °C.

-

Continue to maintain speed at 1800...2200 rpm until specification "B1-S1 OK" appears in display zone 4.

If the specifications are obtained:

-

Release accelerator pedal and brake pedal.

-

Press -> key.

-

Press keys 0 and 6 for function "End output" and confirm entry with Q key.

-

Switch ignition off.

If the specifications are not attained:

-

Road test vehicle to free oxygen sensor of possible residues and repeat test.

Observe the valid safety precautions when carrying out a road test. See: Computers and Control Systems/Service Precautions/Technician Safety
Information 

If the specifications are again not attained:

-

Replace heated oxygen sensor -G39-.

-

Check DTC Memory, if necessary, repair any malfunctions and then Erase DTC Memory,Checking and Erasing DTC Memory. Refer to
"Displaying and Reading Trouble Codes/With Manufacture Scan Tool/Check DTC Memory (Function 02)" See: Computers and Control
Systems/Testing and Inspection 

-

Read readiness code. If DTC memory has been erased or engine control module was disconnected from permanent positive, readiness code must
be generated again: Refer to "Monitors, Trips and/or Drive Cycle/ Reading Readiness Code" See: Computers and Control Systems/Testing and
Inspection  
Engine code AWP, Refer to "Monitors, Trips and/or Drive Cycle/Generating Readiness Code" See: Computers and Control Systems/Testing and
Inspection 

Oxygen Sensor (O2S) Before Catalytic Converter|Page 2575 > < Oxygen Sensor (O2S) Before Catalytic Converter|Page 2573