Jetta GLX V6-2.8L (AFP) (2002)
-
Disconnect 6-pin harness connector from throttle valve control module (arrow).
-
Connect multimeter to measure voltage at terminals -2- and -6-.
-
Switch ignition on.
Specified value: min. 4.5 V
-
Switch ignition off.
-
Connect multimeter to measure voltage at harness connector terminal -2- and Ground.
-
Switch ignition on.
Specified value: min. 4.5 V
-