Expansion Block/Orifice Tube: Testing and Inspection
Restrictor and Reservoir (With Internally Regulated Compressor), Checking

Restrictor And Reservoir (with Internally Regulated Compressor), Checking

NOTE:

-

Connect service station.

-

Observe test conditions.

-

Set engine speed to 2000 RPM.

-

Observe pressure gauge of service station.

NOTE:
-

Switching pressures for refrigerant circuit switches are vehicle-specific.

-

Connection with valve for low-pressure switch or at evaporator is only to be used for vehicles with no service connection on low-pressure side
and an inaccessible connection at compressor or reservoir (measurement accuracy). Only applies to certain vehicles.

Specified values:

High pressure side:

Increasing from initial pressure (on connecting pressure gauges) to max. 20 bar.

Low pressure side:

Decreasing from initial pressure (on connecting pressure gauges) to value in graph.

A. High pressure (measured at service connection) in bar.
B. Low pressure (measured at connection with valve at compressor or reservoir) in bar.
C. Permissible tolerance range.
D. Low pressure (measured at connection with valve for low-pressure switch or at service connection) in bar.
E.  Permissible tolerance range.