Expansion Valve: Testing and Inspection
Expansion Valve and Receiver (Without Internally Regulated Compressor), Checking

Expansion Valve And Receiver (Without Internally Regulated Compressor), Checking

Test requirements

-

Radiator and condenser clean (clean if necessary).

-

Ribbed belt for A/C compressor and generator is correctly tensioned.

-

All air ducts, covers and seals OK and properly installed.

-

Flaps reach their end positions.

-

Engine at normal operating temperature.

-

Evaporator and heater not drawing in secondary air at maximum fresh-air blower speed.

Note the following points when engine is running and A/C system set to maximum cooling output:

-

Fresh air blower running.

-

Coolant fan in operation or is switched on.

-

Recirculating/fresh air door in "recirculating air" position.

-

Ambient temperature greater than 15 degrees C.

-

A/C Evaporator Temperature Switch E33 is correctly installed and its switching temperatures are OK.

Checking

-

Switch ignition off.

-

Connect pressure gauge set (service station).

-

Take pressure gauge reading. Two results A and B can be displayed.

Ambient temperature

Pressure in refrigerant circuit in

in degrees Celsius

bar positive pressure

+15 degrees C

3.9

+20 degrees C

4.7

+25 degrees C

5.6

+30 degrees C

6.7

+35 degrees C

7.8

+40 degrees C

9.1

+45 degrees C

10.5

A. Pressure in refrigerant circuit is lower than indicated in the table, not enough refrigerant in circuit.
-

Localize leak using leak detector.

-

Pressure relief valve opened, check activation for coolant fan according to wiring diagram.

Check for constricted refrigerant pipe and hose cross-sections caused by inadequate bending radii or external damage. If no malfunction can be found,
flush refrigerant circuit.

B. Pressure in refrigerant circuit in line with table or higher.
-

Start engine.

-

Set air conditioning system to maximum cooling output.

-

Open doors.

-

Open air vents in instrument panel.

Engine drives A/C compressor by ribbed belt via A/C Clutch.

NOTE:

-

If A/C compressor is not being driven, check voltage supply for A/C Clutch N25 according to wiring diagram.

-

If A/C compressor is not being driven, check voltage supply for A/C Clutch N25 according to wiring diagram.

If A/C compressor is driven, check refrigerant circuit:

-

Set engine speed to 2000 RPM.

-

Observe pressure gauge set.

Specified values

High pressure side:

Increasing from pressure with engine switched off up to maximum 20 bar positive pressure.

Low pressure side:

Expansion Valve and Receiver (With Internally Regulated Compressor), Checking|Page 12034 > < Expansion Valve and Receiver (With Internally Regulated Compressor), Checking|Page 12032