Jetta Sedan L5-2.5L (BGP) (2005)
Housing Assembly HVAC: Procedures
Heating and A/C Unit, Disassembly and Assembly
Heating And A/C Unit, Disassembly And Assembly
1. Central Air Flap Motor V70
-
Checking: Use Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault Finding"
-
Replacing: Initiate Basic Setting using Vehicle Diagnostic, testing info. system VAS 5051/5052
2. Left Temperature Flap Motor V158
-
Checking: Use Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault Finding"
-
Replacing: Initiate Basic Setting using Vehicle Diagnostic, testing info. system VAS 5051/5052
3. Defroster Flap Motor V107
-
Checking: Use Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault Finding"
-
Replacing: Initiate Basic Setting using Vehicle Diagnostic, testing info. system VAS 5051/5052
4. Bracket
5. Screws
-
Remove screws to separate air distribution and evaporator housings.
6. Cover
7. Fresh/Recirculating Air Door Motor V154
-
Checking: Use Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault Finding"
-
Replacing: Initiate Basic Setting using Vehicle Diagnostic, testing info. system VAS 5051/5052
8. Air Flow Flap Motor V71
-
hecking: Use Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault Finding"
-
Replacing: Initiate Basic Setting using Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault
Finding"
9. Air intake housing
-
With recirculating air flap (Climatic)
-
With air flow flap (Climatronic)
10. Evaporator housing - upper part
-
Disassembling and assembling evaporator housing