Jetta Sedan L5-2.5L (CBTA) (2009)
-
Carefully pull off all sealing rings from the hydraulic unit valve domes.
CAUTION!
‹› On a disconnected control module, the circuit board is exposed.
‹› No moisture or particles of dirt must penetrate in the interior of the control module.
‹› Avoid buildup of static electricity!
-
Cover the control module magnetic coils with a lint free cloth.
After separating the control module and hydraulic unit, use the transport protection for the valve body.
Installing the New Control Module
CAUTION!
Excessive shaking (e.g. dropping, impact) may destroy the control module. The control module must then no longer be used.
‹› Surface must be cleaned before assembling.
-
Slide all sealing rings - A - slightly over the valve domes.