panel B.

Specified value: Wire resistance max 1.5 ohms.

If the specification is not obtained:

-

Check the wiring for high resistance or an open circuit.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring or if the voltage supply was OK:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to --> [ Motronic Engine Control Module, Replacing ] .

-

Using a multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical connector terminal 1 to Motronic Engine Control Module (ECM)
(J623) electrical connector T94 terminal 44 for an open circuit or high resistance.

-

Using a multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical connector terminal 2 to Motronic Engine Control Module (ECM)
(J623) electrical connector T94 terminal 49 for an open circuit or high resistance.

Specified value: 1.5 ohms max.

If the specification is not obtained:

-

Check the wiring for a short circuit to Battery positive (+), high resistance or an open circuit.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is found in wiring:

-

Replace the Motronic Engine Control Module (ECM) (J623). Refer to --> [ Motronic Engine Control Module, Replacing ] . 

Assembly is performed in the reverse order of the removal, note the following:

-

Install the right rear wheel housing liner.