volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Operational Readiness of Oxygen Sensor After Catalyst, Checking|Page 5220 > < Operational Readiness of Oxygen Sensor After Catalyst, Checking|Page 5218
Page 16
background image

-

Connect multimeter for voltage measurement to terminals 3 + 4 of connector to Engine Control Module (ECM) and measure primary voltage.
Specified value: 0.40 to 0.50 Volts

-

Switch ignition off.

If specified value is not obtained:

-

Test oxygen sensor wires.

If specified value is obtained:

-

Replace Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130- Bank 1

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Testing and Inspection/Scan Tool
Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

-

Generate readiness code. See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

Checking oxygen sensor wires

-

Connect test box to control module wiring harness. See: Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool
Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test

-

Check wires between test box and 4-pin connector to Motronic control module for open circuit according to wiring diagram.
Terminal 3 + socket 68
Terminal 4 + socket 69
Wire resistance: max: 1.5 Ohms

-

Check wires for short circuit to B+ and Ground (GND).
Specified value: Infinite Ohms

If no malfunctions are found in wires:

-

Replace Engine Control Module (ECM).

Not Available For Manufacturer's Scan Tool

The manufacturer does not provide this procedure using a Manufacturer's Scan Tool.

With Generic Scan Tool

Oxygen Sensor Heater For Oxygen Sensor Before Three Way Catalytic Converter (TWC), Checking

NOTE:  When servicing terminals in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.

Recommended special tools and equipment

-

V.A.G1526 multimeter or V.A.G1715 multimeter

Operational Readiness of Oxygen Sensor After Catalyst, Checking|Page 5220 > < Operational Readiness of Oxygen Sensor After Catalyst, Checking|Page 5218