volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

With Generic Scan Tool|Page 2280 > < With Generic Scan Tool|Page 2278
Page 1
background image

Air Flow Meter/Sensor: Testing and Inspection
With Manufacturer's Scan Tool

Mass Air Flow (MAF) Sensor, Checking

Special tools and equipment

-

V.A.G1551 scan tool or V.A.G1552 mobile scan tool with V.A.G1551/3B cable

-

V.A.G1598/31 test box

-

V.A.G1526 or Fluke 83 multimeter

-

V.A.G1594 adapter set

-

Wiring diagram

Check conditions

-

All fuses must be OK.

-

Coolant temperature must be at least 80 degrees C, see display group 04, display zone 3.

-

All electrical consumers, e.g. lights and rear window defroster must be switched off

-

If the vehicle is equipped with an air conditioner, this must be switched off.

-

On vehicles with automatic transmission selector lever in "P" or "N" position

Test sequence

-

Connect V.A.G1551 scan tool (V.A.G1552). Start engine and select "Address word" 01 of engine control module. Engine must be running at
idling speed. (Connecting scan tool and selecting engine control module. See: Powertrain Management/Computers and Control Systems/Testing
and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan Tool/Connecting VAG 1551
Scan Tool)

Indicated on display:

Rapid data transfer HELP
Select function XX

-

Press keys 0 and 8 for function "Read measured value block" and confirm entry with Q key.

Indicated on display:

Read measured value block HELP
Input display group number XXX

-

Press keys 0, 0 and 2 for "Display group number 2" and confirm entry with Q key.

Indicated on display: (1 to 4 = Display zones)

Read measured value block 2
1 2 3 4

Check the air mass drawn in in display zone 4

Specification: 2.0 to 4.5 g/s

If the specification is obtained but there is a malfunction regarding Mass Air Flow (MAF) sensor registered in the DTC memory:

-

Check voltage supply for Mass Air Flow (MAF) sensor.