volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 2692 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 2690
Page 7
background image

-

Connect multimeter for voltage measurement to terminals 3 + 4 of connector to Engine Control Module (ECM) and measure primary voltage.
Specified value: 0.40 to 0.50 Volts

-

Switch ignition off.

If specified value is not obtained:

-

Test oxygen sensor wires.

If specified value is obtained:

-

Replace Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130-, item 10

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.  See: Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

-

Generate readiness code.  See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

Checking oxygen sensor wires

-

Connect test box to control module wiring harness, connect test box for wiring test.

-

Check wires between test box and 4-pin connector to Motronic control module for open circuit according to wiring diagram.
Terminal 3 + socket 68
Terminal 4 + socket 69
Wire resistance: max. 1.5 ohms

-

Also check wires for short circuit to B+ and Ground (GND).
Specified value: Infinite Ohms

If no malfunctions are found in wires:

-

Replace Engine Control Module (ECM)

With Manufacturer's Scan Tool

Oxygen Sensor And Oxygen Sensor Control Before Three Way Catalytic Converter (TWC), Checking

NOTE:

-

Raise vehicle to reach oxygen sensor connector.

-

The Oxygen Sensor (O2S) before Three Way Catalytic Converter (TWC) has constant regulation and can be distinguished by a 6-pin connector
from the Oxygen Sensor (O2S) behind the Three Way Catalytic Converter (TWC).

-

Only gold terminals may be used for servicing the terminals in the connector for the oxygen sensor.

Special tools, test equipment and auxiliary items

-

VAG 1551 scan tool or VAG 1552 mobile scan tool with VAG 1551/3B cable

-

VAG 1598/31 test box

-

VAG 1526 hand multimeter or VAG 1715 multimeter

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 2692 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 2690