volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor and Oxygen Sensor Control Before Catalytic Converter, Checking|Page 4463 > < Diagram Information and Instructions|Page 4460
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor and Oxygen Sensor Control Before Catalytic Converter, Checking

Oxygen Sensor And Oxygen Sensor Control Before Catalytic Converter, Checking

NOTE:

-

Vehicle must be raised before the oxygen sensor connector is accessible.

-

When servicing terminals in harness connector of oxygen sensor, use only gold-plated terminals.

Recommended special tools and equipment

-

V.A.G 1526 multimeter or V.A.G 1715 multimeter

-

V.A.G 1594 connector test kit

-

Wiring diagram

Test requirements

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G39- must be OK.

-

Battery voltage must be at least 11.5 volts.

-

All electrical consumers such as: lights and rear window defroster must be switched off.

-

Parking brake must be engaged or else day time driving lights will be switched on.

-

If vehicle is equipped with an A/C system, it must be switched off.

-

For vehicles with automatic transmission, selector lever must be in -P-.

-

Ground (GND) connections between engine and chassis must be OK.

-

Exhaust system must be properly sealed between catalytic converter and cylinder head.

-

Coolant temperature must be at least 80 degrees C. Diagnostic mode 1: Check measured values; PID 5, Coolant temperature. See: Testing and
Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 1: Check Measured Values

-

Oxygen sensor heater for oxygen sensor before catalytic converter must be OK, check. See: Oxygen Sensor Heater For Oxygen Sensor Before
Three Way Catalytic Converter (TWC), Checking

Function test

-

Select the following output of oxygen sensor signals and check whether the specified values are being reached. Diagnostic mode 5: Check output
of oxygen sensor signals. See: Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check
Output of Oxygen Sensor Signals

-

End diagnosis and switch ignition off.

If specified values are not obtained:

-

Check oxygen sensor wires to control module according to wiring diagram.

Checking oxygen sensor wires to control module

Oxygen Sensor and Oxygen Sensor Control Before Catalytic Converter, Checking|Page 4463 > < Diagram Information and Instructions|Page 4460