Air Bypass Valve: Testing and Inspection
Charge Pressure Control Valve Pressure Unit, Checking

Charge Pressure Control Valve Pressure Unit, Checking

Requirements

-

Engine oil temperature 60 degrees C min.

-

No leaks on intake and exhaust systems.

Work sequence

-

Disconnect connector - 2 - from Wastegate bypass regulator valve -N75- -1 -.

-

Start engine and bring to maximum engine speed by accelerating spontaneously. Operating rod - 2 - for charge pressure control valve must move.

If the operating rod does not move:

-

Check charge pressure control valve lever -1 - for ease of operation. If rusted in place, replace turbocharger.

If the operating rod does not move even though the lever moves freely:

-

Replace turbocharger