volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Starting and Charging|Service and Repair > < Battery Without Charge Indicator (Magic Eye), Checking|Page 7902
Page 13
background image

-

If specific density is too low, charge battery and recheck specific density afterwards.
-

Electrolyte density must not vary more than 0.04 kg/cu.cm between cells.

Examples of unacceptable variations in specific gravity:

Example 1: Specific gravity in cell 4 (1.10) is too low.

Example 2: Specific gravity in cells 4 (1.10) and 5 (1.18) are too low and variation between cells exceeds 0.04 kg/cu.cm.

If specific gravity specifications are not met, replace battery.

If specific gravity specifications are met, reinstall cell caps.

CAUTION:  Only the use of genuine VW battery cell caps ensures the different battery cover systems are sealed correctly. Only use genuine cell caps of
the same construction if lost or damaged. All cell caps must be equipped with an O-ring seal.