Receiver Dryer: Service and Repair

Receiver or Reservoir and Restrictor, Replacing

Replacing after flushing refrigerant circuit, e.g. on account of ingress of moisture (refrigerant circuit open for lengthy period) or contamination

-

Discharge refrigerant circuit.

-

Remove A/C compressor.

-

Rectify cause of trouble.

-

Clean (flush) refrigerant circuit with compressed air and nitrogen.

-

Examine expansion valve for dirt or corrosion; replace if necessary.

-

Remove oil drain plug from compressor.

NOTE:  The oil drain plug of "Denso/Nippondenso" compressors is installed with an oil seal instead of an O-ring and this is always to be replaced

-

To accelerate drainage of refrigerant oil, rotate compressor e.g. by way of clutch plate of A/C clutch for example.

-

Pour old refrigerant oil out of compressor, see HSO Environment Vol. 2-2. 43. 1.

-

Then fill compressor with quantity of fresh refrigerant oil corresponding to quantity of refrigerant oil in replacement compressor.

NOTE:
-

Use different refrigerant oils and quantities for the various compressors.

-

To ensure compressor lubrication on start-up, at least 80 cu.cm of refrigerant oil must be poured into the compressor, the remainder can be
added for example to the new reservoir or receiver.

-

If dirt has penetrated into the compressor with the refrigerant circuit open (e.g. after an accident), compressor is to be replaced.

-

Replace receiver or reservoir and restrictor.

-

Assemble, evacuate and charge refrigerant circuit.

Replacing without the need for flushing refrigerant circuit with compressed air and nitrogen (e.g. in the event of accident damage); no escape
of refrigerant and no penetration of moisture and dirt into circuit

-

Discharge refrigerant circuit.

-

Replace restrictor.

-

Remove receiver or reservoir.

-

Remove dirt from receiver or reservoir.

-

Weigh receiver or reservoir removed.

NOTE:
-

Add refrigerant oil to new receiver or reservoir until weight of component removed has been attained.

-

Install new receiver or reservoir.

-

Assemble, evacuate and charge refrigerant circuit.