volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Knock Sensor > < Intake Air Temperature (IAT) Sensor G42|Page 3617
Page 6
background image

-

Measure resistance at Intake Air Temperature (IAT) sensor -G42-, terminals 1 (signal) and 3 (Ground).

Range A displays resistance values for temperature range of 0 to 50 degrees C, range B displays resistance values for the temperature range of 50 to 100
degrees C
.

Read-out examples:

-

30 degrees C is in range A and corresponds to a resistance of 1.5 to 2.0 kohms

-

80 degrees C is in range B and corresponds to a resistance of 275 to 375 Ohms

If specified value is not obtained:

-

Replace Mass Air Flow (MAF) sensor -G70- with Intake Air Temperature (IAT) sensor -G42-.

-

Erase DTC memory of Engine Control Module (ECM). Diagnostic mode 4: Reset/erase diagnostic data. See: Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

-

Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If no malfunctions are detected in the wires and the resistance values are OK:

-

Replace Motronic Engine Control Module (ECM) -J220-.

Knock Sensor > < Intake Air Temperature (IAT) Sensor G42|Page 3617