volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Fuel Gauge Sender|Locations|Page 1369 > < Fuel Gauge Sender|Locations
Page 2
background image

13. Fuel tank
14. Heat shield

-

For fuel tank

15. Clamping washer
16. Cover for fuel tank
17. 25 Nm
18. Tension strap

-

Note varying lengths

-

Installation position: Locating point (hole) faces direction of travel

19. Fuel filter (vehicles with engine code AEG, AVH, AZG)

-

Installation position: Arrow points in direction of flow

-

Fuel filter with attachments, removing and installing (vehicles with engine code BEV, BGD).

20. Screw clamp

-

Vehicles with engine code AEG, AVH, AZG

-

Note installed position, see below Fig. 4

21. Supply line

-

Black

-

Check for secure fit

-

To remove from fuel filter, press release buttons on connecting piece

Vehicles with engine code AEG, AVH, AZG
-

To fuel supply line at fuel distributor.

Vehicles with engine code BEV
-

To fuel supply line at fuel distributor.

Vehicles with engine code BGD
-

To fuel supply line at fuel distributor.

22. Ventilation line

-

White

-

Clipped in at top of fuel tank

-

Check for secure fit

-

To Evaporative Emission (EVAP) canister purge regulator valve -N80-.

23. Seal

-

Replace if damaged

-

To install, place into opening of fuel tank when dry

-

Only coat with fuel when installing Fuel Pump (FP) flange

24. Fuel Pump (FP) unit

-

Note installation position of flange at fuel tank, see below Fig.  1.

-

Clean strainer if dirty

25. Union nut, 75 Nm
26. Supply line

-

Black

-

Check for secure fit

-

Clipped in sideways at fuel tank

-

To remove from flange and fuel filter, press release buttons on connecting piece

27. Return line

-

Blue or with blue marking

-

Clipped in sideways at fuel tank

-

Check for secure fit

-

To remove from flange, press release buttons on connecting piece

Vehicles with engine code AEG, AVH, AZG
-

From fuel return line at fuel distributor.

Vehicles with engine code BEV, BGD
-

From fuel pressure regulator.

28. Gravity valve

-

To remove, unclip valve upward from connection

-

Check valve for throughput. Valve vertical: open, Valve tilted 45 degrees: closed

29. Pressure retention valve

-

Checking, see below Fig. 3

30. Ground (GND) connection

-

Check for secure fitting

Fig. 1 Installation position of Fuel Pump (FP) flange

Fuel Gauge Sender|Locations|Page 1369 > < Fuel Gauge Sender|Locations