volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Fuel Gauge|Service and Repair|Page 9909 > < Fuel Gauge|Service and Repair
Page 2
background image

IMMO-IDENT No.: VWZ7Z0V0066808

->

-

Press -Q- button to confirm input.

Indicated on display (select function):

Rapid data transfer

HELP

Select function XX

-

Press buttons -1- and -0- to select function 10 "Adaptation".

Indicated on display:

Rapid data transfer

Q

10 - Adaptation

-

Press -Q- button to confirm input.

Indicated on display:

Adaptation
Enter channel number XX

-

Press buttons -3- and -0- to select channel 30.

Indicated on display:

Adaptation

Q

Enter channel number 30

-

Press -Q- button to confirm input. 

Indicated on display:

Channel 30 Adaptation 128

->
<-1 3->

-

Use button 1 to decrease adaptation value down to 120

-

Use button 3 to increase value up to 136, e.g. 130.

Indicated on display:

Channel 30 Adaptation 130

Q
<-1 3->

Adaptation is correct when the fuel gauge needle is positioned on the middle of the three red graduations (reserve) as illustrated.

Fuel Gauge|Service and Repair|Page 9909 > < Fuel Gauge|Service and Repair