volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Operational Readiness Oxygen Sensor|Page 2851 > < Operational Readiness Oxygen Sensor|Page 2849
Page 5
background image

Indicated on display (1-2 = Display zones)

Read Measuring Value Block 30

->

2

-

Check status of the oxygen sensor control before catalyst (display zone 1):
Specification: 111

Significance of 3 digit number block in display zone 1

NOTE:  The first position of the 3 digit number block fluctuates between 0 and 1 (Heated oxygen sensor on and off).

If the specification is not obtained:

-

Check Heated oxygen sensor before catalyst.  

If the specification is obtained:

-

Change to display group 32 as follows:

-

Press C button.

-

Press buttons 0, 3 and 2 for "Display group number 32" and confirm entry with Q button.

Indicated on display: (1 to 2 = Display zones)

Read measured value block 32

->

2

-

Check oxygen sensor control learned value at idling (additive) in display zone 1.
Specification: -10.0 to 10.0 %

-

Check oxygen sensor control learned value at part load (multiplicative) in display zone 2.
Specification: -10.0 to 10.0 %

If the specification is not obtained:

-

Evaluating display group 32 Refer to "Scan Tool Testing/Measuring Value Blocks/Evaluating Measured Value Blocks/Display Groups 30 to 49,
107 (Oxygen Sensor Control)" See: Testing and Inspection 

If the specification is obtained:

-

Change to display group 33 as follows:
VAG 1551: Press button 3
V.A.G 1552: Press button Uparrow

Indicated on display (1-2 = Display zones)

Read Measuring Value Block 33

->

Operational Readiness Oxygen Sensor|Page 2851 > < Operational Readiness Oxygen Sensor|Page 2849