volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Operational Readiness Oxygen Sensor|Page 1143 > < Operational Readiness Oxygen Sensor|Page 1141
Page 25
background image

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G130- must be OK.

-

Ignition switched off.

Test sequence

-

Unscrew protective cover (arrows) and disconnect 4-pin harness connector (brown) -1- to Oxygen Sensor (O2S) behind Three Way Catalytic
Converter (TWC) -G130-.

Vehicles with engine code AEG, AVH, AZG

-

Check resistance for sensor heater at connector to oxygen sensor terminal 1 + 2. Specified value: 1.0...5.0 Ohms (at room temperature)

Vehicles with engine code BDC

-

Check resistance for sensor heater at connector to oxygen sensor terminal 1 + 2. Specified value: 8.0...20.0 Ohms (at room temperature)

Continuation for all vehicles

If specified value is not obtained:

-

Replace Oxygen Sensor (O2S) 2 Bank 1 Behind Three Way Catalytic Converter (TWC) -G130-.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.  

-

Generate readiness code.  See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles
and Readiness Codes

If specified value is obtained:

-

Check Ground (GND) activation of oxygen sensor heater.