New Beetle L5-25L (BPR) (2007) Air Door Cable Location
Air Door Cable: Description and Operation
Heating and Ventilation Cables
‹› Cable sleeve ends are color coded.
‹› Check cables before installing. Replace binding or damaged cables.
‹› Attach cables to removed controls first and then attach to levers at heating and ventilation unit.
‹› All air doors must audibly move onto end stops when turning controls.
1
Central door cable
‹› From air distribution rotary control to central door
‹› Cable sleeve marking: Yellow
‹› Installing and adjusting => [ Central Door Cable ] See: Service and Repair/Central Door Cable
2
Footwell/defrost door cable
‹› From air distribution rotary control to footwell/defrost door
‹› Cable sleeve marking: Green
Removing
-
Remove heating and ventilation controls => [ Heating and Ventilation Controls ] See: Control Assembly/Service and Repair/Heating and
Ventilation Controls