New Beetle L5-2.5L (BPR) (2007)
5
A-Pillar
6
A-Pillar Trim
7
Window Adjuster
‹› (443 845 631 A)
8
Outer Plenum Chamber Cover
9
PUR Adhesive Sealant Joint
‹› Central within area of dimension - b - = 130 to 170 mm
Undamaged Window, Preparing For Glazing
Flush-Bonded Windows
Undamaged Window, Preparing for Glazing
‹› When re-using an undamaged window, cut back remaining adhesive sealant to 1 to 2 mm shortly before re-adhering, do not damage primer and
ceramic coating.
‹› Residual material acts as a base for the new adhesive sealing material.
‹› Do not prime or use a cleaning solution on the adhesive surface. Keep adhesive surface free of dirt and grease.
‹› Exception: If bonding is not performed immediately after cutting back, the remaining material must be activated using the Activator ( D 181 801
A1).
Window Flange, Preparing For Glazing
Flush-Bonded Windows
Window Flange, Preparing for Glazing
-
Cut back remaining material using scraper (V.A.G 1561/8 ), do not remove all residue under any circumstance.