volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Air Injection Flow Sensor > < Generic Scan Tool|Page 5787
Page 1
background image

Air Injection Control Valve: Service and Repair

Secondary Air Injection Solenoid Valve, Checking

Special tools, testers and auxiliary items required

‹› Connector test set (VAG 1594C)

‹› Assisting hose, for example, coolant hose

Sequence

‹› Do not use compressed air during the following check!

-

Remove the engine cover.

-

Disconnect the pressure hose - 2 - from Secondary Air Injection (AIR) solenoid valve (N112) - 3 -. To do so, compress the securing ring.

-

Disconnect the harness connector - 4 -.

-

Slide the assisting hose - 1 -, for example, coolant hose, into the AIR solenoid valve.

-

Blow forcefully into the assisting hose - arrow -. 

Valve must be closed.

If air can be blown through the valve with the assisting hose properly sealed:

-

Replace the AIR solenoid valve.

If valve is closed:

-

Connect terminals on the connector connection - 5 - with adapter cables from (VAG 1594C) to the battery positive (+) and negative (-).

-

Blow forcefully into the assisting hose - arrow -. 

Valve must be opened.

If no air can be blown through the valve with the assisting hose properly sealed:

-

Replace the AIR solenoid valve.

Air Injection Flow Sensor > < Generic Scan Tool|Page 5787