volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor Before Catalytic Converter, Checking Heater|Page 5685 > < Oxygen Sensor Before Catalytic Converter, Checking Heater|Page 5683
Page 8
background image

If the specified value was obtained:

-

Replace the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G130)..

If the specified value was Not obtained:

Checking wiring

If the manufacturers test box is being used, perform the following step.

-

Install the test box.

If the manufacturers test box is not being used, perform the following step.

-

Remove the Engine Control Module (ECM) (J220). Refer to the Repair Information.

-

Using a multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector
terminals to the Engine Control Module (ECM) ( J220) electrical harness connector T121 terminals for resistance. 

Specified value: 1.5 ohms Max.

If the specified value was Not obtained:

-

Check the wiring for an open, high resistance, short circuit to each other, Battery (+) or Ground.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring and the voltage supply was Not OK:

-

Replace the Engine Control Module (ECM) (J220 ). Refer to the Repair Information.

-

Install the right side vehicle O2S connector cover.

Final procedures

After repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] See: Testing and Inspection/Scan Tool Testing and

Procedures/Diagnostic Modes 01 - 09. 

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] See: Testing and Inspection/Scan Tool Testing

and Procedures/Diagnostic Modes 01 - 09.

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] See: Testing and Inspection/Monitors, Trips, Drive

Cycles and Readiness Codes/Readiness Code.

Oxygen Sensor Before Catalytic Converter, Checking

Diagnostic Procedures

Oxygen Sensor before Catalytic Converter, Checking

‹› Use only gold-plated terminals when servicing terminals in the electrical harness connector of the Heated Oxygen Sensor (HO2S) (G39 ).

Special tools, testers and auxiliary items required

‹› Multimeter.

Oxygen Sensor Before Catalytic Converter, Checking Heater|Page 5685 > < Oxygen Sensor Before Catalytic Converter, Checking Heater|Page 5683