New Beetle Convertible L5-2.5L (BPR) (2007)
-
Remove the bolt - 3 -.
-
Remove the bolts - 1 and 2 -.
-
Remove the Evaporative Emission (EVAP) canister with the Leak Detection Pump (LDP) (V144).
Removing the LDP
-
Disconnect the connecting hose from the LDP.
-
Remove the three bolts.
-
Remove the LDP from the EVAP canister
Installing
Installation is performed in the reverse order of removal. When doing this note the following:
‹› Connect ventilation lines until they engage audibly.
‹› Make sure lines and EVAP canister are locked securely.
Tightening Specifications