Read Measuring Value Block 33

->

2

-

Observe oxygen sensor control in display zone 1. Display must fluctuate at least 2 % in range
-10.0 to 10.0%

If the oxygen sensor control in display zone 1 does not fluctuate as stated:

-

Press -> button.

-

Press buttons 0 and 6 for "End data transfer" function and confirm input with Q button. 

-

Switch ignition off.

-

Carry out a test drive to remove possible residue on oxygen sensor and repeat check.

Observe the valid safety precaution carrying out a road test.

If the specifications in display zone 1 are not obtained even after a test drive, or the value does not fluctuate by at least 2 %:

-

Replace oxygen sensor before catalyst (G39).

-

Check DTC memory, if necessary, repair any malfunctions and then erase DTC memory. Refer to "Displaying and Reading Trouble Codes/With
Manufacturers Scan Tool/DTC Memory Checking and Erasing" See: Computers and Control Systems/Testing and Inspection 

Checking oxygen sensor wiring for oxygen sensor 1

-

Remove inner plenum chamber cover, left:

-

Connect test box V.A.G 1598/31 to control module wiring harness. The engine control module is not connected by this action.

-

Remove protective cover -arrows and separate 6-pin connector (black) - 1- to oxygen sensor before catalyst (G39).