Page 21
background image

-

All fuses must be OK

-

The battery voltage must be at least 11.5 V

-

Fuel pump relay must be OK

Test sequence

-

Connect scan tool VAG 1551 (V.A.G 1552). Start engine and select "Address word" 01 of engine control module. When doing this engine must be
running at idle speed.

Connecting scan tool and selecting engine control module. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks/VAG1551 Scan
Tool"See: Powertrain Management/Computers and Control Systems/Testing and Inspection 

Indicated on display

Rapid data transfer 

HELP

Select function XX

-

Press buttons 0 and 8 for function "Read Measuring Value Block" and confirm entry with Q button.

Indicated on display

Read Measuring Value Block 
Input display group number XXX

-

Press buttons 0, 4 and 1 for "Display group number 41" and confirm entry with Q button.

Indicated on display (1-4 = Display zones)

Read Measuring Value Block 41

->

4

-

Let engine run 2 minutes at idle speed.

-

Check status of heated oxygen sensor before catalytic converter in display field 2.

Display: Htg.bC.ON, Htg.aC.OFF (alternating)

NOTE:  The heated oxygen sensor may be switched on or off depending on the operating conditions of the engine, therefore the display in display zone
2 may show "Htg.bC.ON or alternating from Htg.bC.ON to Htg.bC. OFF.

If the specification is obtained:

-

Press -> button.

-

Press buttons 0 and 6 for function "End output" and confirm entry with Q button.

-

Switch ignition off.

If the specifications are not obtained:

-

Press -> button.

-

Press buttons 0 and 6 for function "End output" and confirm entry with Q button.

-

Switch ignition off.