volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Operational Readiness Oxygen Sensor|Page 798 > < Operational Readiness Oxygen Sensor|Page 796
Page 29
background image

-

Set multimeter to measure voltage and connect to terminal / (connector to engine control module) and Ground.

-

Start engine and run at idle speed.

-

Measure voltage supply:
Specification: 11.0 to 14.5 V

If the specification is not obtained:

-

Check wiring between terminal 1 and fuel pump relay (J17) using wiring diagram.

Checking voltage supply

-

Connect multimeter using auxiliary cables from VAG 1594 to measure voltage at terminals 1 + 2 (connector to engine control module).

-

Start engine and run at idle speed.

-

Measure voltage supply and observe display group 41, display zone 4.
Display: Htg.aC.ON:
-

Specification: 11.0-14.5 V

Display: Htg. aC.ON/Htg.aC.OFF (alternating):
-

Specification: Between 0.0-12.0 V fluctuating

-

Switch ignition off.

If no voltage is present:

-

Remove inner plenum chamber cover, left:

Operational Readiness Oxygen Sensor|Page 798 > < Operational Readiness Oxygen Sensor|Page 796