volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3980 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3978
Page 7
background image

-

When servicing terminals in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.

Recommended special tools and equipment

-

VAG1526 multimeter or VAG1715 multimeter

-

VAG1594 connector test kit

-

Wiring diagram

Test requirements

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G39- must be OK.

-

Battery voltage must be at least 11.5 volts.

-

All electrical consumers such as, for example, lights and rear window defroster must be switched off.

-

Parking brake must be engaged or else daylight driving lights will be switched on.

-

If vehicle is equipped with an A/C system, it must be switched off.

-

Ground (GND) connections between engine and chassis must be OK.

-

Exhaust system must be properly sealed between catalytic converter and cylinder head.

-

Coolant temperature must be at least 80 degrees C, Diagnostic mode 1: Check measuring values; PID 5, Coolant temperature.  See: Testing and
Inspection/Scan Tool Testing and Procedures/Read Measuring Value Blocks (Function 08)/With Generic Scan Tool/Diagnostic Mode 1: Check
Measured Values

-

Oxygen sensor heaters for oxygen sensors before catalytic converter must be OK, check.  See: Testing and Inspection/Component Tests and
General Diagnostics/Oxygen Sensor Heater Before Three-Way Catalytic Converter (TWC), Checking

Function test

-

Select the following output of oxygen sensor signals and check whether the specified values are being reached, Diagnostic mode 5: Check output
of oxygen sensor signals.  See: Testing and Inspection/Scan Tool Testing and Procedures/Read Measuring Value Blocks (Function 08)/With
Generic Scan Tool/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals

If specified values are obtained:

-

End diagnosis and switch ignition off.

If specified values are not obtained:

-

Test oxygen sensor wires.

Checking oxygen sensor wires

-

Unscrew protective cover (arrows) and disconnect 6-pin harness connector (black) -1- to Heated Oxygen Sensor (HO2S) -G39- before catalytic
converter.