Perform resistance measurement at intake air temperature sensor(G42) terminals 1 (signal) and 2 (Ground).

Scale A shows resistance values for temperature range 0 to 50 °C and scale B the values for temperature range 50 to 100 °C.

Examples:

-

30 °C is in range A and corresponds to a resistance of 1.5 to 2.0 k Ohms

-

80 °C is in range B and corresponds to a resistance of 275 to 375 Ohms

If the specification is not obtained:

-

Replace intake air temperature sensor (G42)

-

Check DTC memory, if necessary, repair any malfunctions and then erase DTC memory. See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Reading Diagnostic Trouble Codes  

-

Read readiness code. If DTC memory has been erased or engine control module was disconnected from permanent positive, readiness code must
be generated again. 

See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes 
See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes 

If there is no malfunction in the wiring and the resistance measurement values are OK:

-

Replace engine control module.

-

Check DTC memory, if necessary, repair any malfunctions and then erase DTC memory. See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Reading Diagnostic Trouble Codes  