Connect multimeter for voltage measurement to terminals 3 + 4 of connector to Engine Control Module (ECM) and measure primary voltage. 
Specified value: 0.400 to 0.500 Volts

-

Switch ignition off.

If specified value is not obtained:

-

Test oxygen sensor wires.

If specified value is obtained:

-

Replace Oxygen Sensor (O2S) 2 Bank 1 Behind Three Way Catalytic Converter (TWC) -G130-:
-

Vehicles with engine code AEG, item 10,

-

Vehicles with engine code AVH, AZG, BDC, item 11.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.  

-

Generate readiness code.  See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

Checking oxygen sensor wires

-

Connect test box to control module wiring harness, connect test box for wiring test.  See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring
Test

Vehicles with engine code AEG

-

Check wires between test box and 4-pin connector (to control module) for open circuit according to wiring diagram.
-

Terminal 3 + socket 51

-

Terminal 4 + socket 52

-

Wire resistance: max. 1.5 Ohms

Vehicles with engine code AVH, AZG, BDC

Operational Readiness Oxygen Sensor|Page 1968 > < Operational Readiness Oxygen Sensor|Page 1966