volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Operational Readiness Oxygen Sensor|Page 742 > < Operational Readiness Oxygen Sensor|Page 740
Page 7
background image

converter.

-

Check wires between test box and 6-pin connector (to control module) for open circuit according to wiring diagram.
-

Terminal 1+socket 70

-

Terminal 2+socket 71

-

Terminal 5 + socket 51

-

Terminal 6 + socket 52

-

Wire resistance: max. 1.5 Ohms

-

Also check wires for short circuit to B+ and Ground (GND). 

Specified value: Infinite Ohms

If no malfunctions are found in wires:

-

Replace Heated Oxygen Sensor (HO2S) 1 Bank 1 -G39- before catalytic converter, item 2.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.  

-

Generate readiness code.  See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles
and Readiness Codes

With Manufacturer Scan Tool

Oxygen Sensor And Sensor Control Before Catalyst, Checking

NOTE:

-

Raise vehicle to reach oxygen sensor connector

-

The oxygen sensor (before catalyst) has constant regulation and can be distinguished by a 6-pin connector from the oxygen sensor after catalyst.

-

Only gold-plated terminals must be used to repair the terminals in the oxygen sensors connectors.

Special tools and equipment

-

Scan tool VAG 1551 or vehicle system tester V.A.G 1552 with cable VAG 1551/3B

-

Test box VAG 1598/31

-

Hand multimeter V.A.G 1526 or multimeter V.A.G 1715

-

Adapter set V.A.G 1594

-

Wiring diagram

Check conditions

Operational Readiness Oxygen Sensor|Page 742 > < Operational Readiness Oxygen Sensor|Page 740