Possible causes of malfunction if sensor control frequency is too slow:

-

Slots or holes in sensor body are blocked

-

Sensor vent hole in area of connecting wire is blocked

-

Sensor has been overheated (glazed)

-

Sensor has been damaged by leaded fuel

Checking basic voltage for oxygen sensor 2

-

Remove protective cover -arrows- and separate 4-pin connector (black/brown) -1- to Oxygen Sensor (O2S) after Three Way Catalytic Converter
(TWC) -G130-.

-

Connect multimeter with auxiliary cables from VAG 1594 to measure voltage at terminals 3 + 4 (connector to Motronic control module).

-

Start engine and measure basic voltage.

Specification: 0.400 to 0.500 V

-

Switch off ignition.