Oxygen Sensor: Testing and Inspection
Oxygen Sensor & O2 Sensor Regulation Before Converter, Check

With Manufacturer's Scan Tool

Oxygen Sensor And Oxygen Sensor Control Before Three Way Catalytic Converter (TWC), Checking

NOTE:

-

Raise vehicle to reach oxygen sensor connector.

-

The Oxygen Sensor (O2S) before Three Way Catalytic Converter (TWC) has constant regulation and can be distinguished by a 6-pin connector
from the Oxygen Sensor (O2S) behind the Three Way Catalytic Converter (TWC).

-

Only gold terminals may be used for servicing the terminals in the connector for the oxygen sensor.

Special tools, test equipment and auxiliary items

-

VAG 1551 scan tool or VAG 1552 mobile scan tool with VAG 1551/3B cable

-

VAG 1598/31 test box

-

VAG 1526 hand multimeter or VAG 1715 multimeter

-

VAG 1594 adapter set

-

Electrical Wiring Diagram

Test conditions

-

All fuses must be OK

-

Battery voltage must be at least 11.5 V

-

Exhaust system between Three Way Catalytic Converter (TWC) and cylinder head must be free of leaks

-

Engine Coolant Temperature (ECT) must be at least 80 °C, see display group 04, display zone 3

Functional check

-

Connect VAG 1551 scan tool ((VAG 1552). Start engine and select "Address word" 01 of Motronic Engine Control Module (ECM) -J220-.
Engine must be running at idle speed. Connecting scan tool and selecting Motronic Engine Control Module (ECM) -J220-. See: Powertrain
Management/Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool
Connecting/With Manufacturer's Scan Tool/Connecting VAG 1551 Scan Tool 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -0- and -8- for function "Read measuring value block" and confirm entry with -Q- button.

Indicated on display

Read measuring value block
Input display group number XXX

-

Press buttons -0-, -3- and -0- for "Display group number 30" and confirm entry with -Q- button.