Passat GLX V6 V6-2.8L (ATQ) (2001)
Odometer: Service and Repair
From 08.99, Up To 10.00
Adaptation (function 10)
Use this function to initiate and store the following changes:
-
Adaptation of odometer reading when replacing/exchanging instrument cluster
-
Adaptation of fuel gauge reading
-
Adaptation of fuel consumption indicator (MFI)
-
Coding Navigation system display language versions (if available)
Individual functions are called up using the appropriate channel number from adaptation table.
Adaption table:
Adaption channel
Adaption functions
03
Fuel consumption indicator adaptation
04
Language versions for Navigation system display
09
Odometer adaptation
16
Distance impulse number (K number): Read only, cannot be change
30
Fuel gauge, checking ! (adaptation)
*) If available
NOTE: After changing an adaption value or ending an adaption channel the function "10 - Adaption" must be performed to select another adaption
channel!
Odometer adaptation
NOTE:
-
The total distance travelled can be read from the malfunctioning instrument cluster, or determined by the vehicle service history.
-
The total distance travelled display of new instrument cluster must not be more than 100 km (63 mi) before adaptation.
-
The total distance travelled to be transferred to the new instrument cluster must exceed 700 km (63 mi).
-
Adapting the total distance travelled is only possible once and only in a positive (up wards) direction.
-
Adaptation can be interrupted with the "C" button of the VAG 1551/1552 Scan Tool (ST)
-
Correcting a false entry which has been confirmed is not possible. The instrument cluster must be exchanged for a new one.
-
Adaptation value must be entered in kilometers. For US models, adaptation value must be converted from miles to kilometers first (miles x 7.609
= kilometers).
Example :
The malfunctioning instrument cluster has an odometer display of 89627 km. The odometer display can be transferred to the new instrument cluster as
follows:
-
Connect VAG 1551 Scan Tool (ST), select 1 "Rapid Data Transfer", switch on ignition, input address word 17 "Instrument cluster".
-
Press -Q- button to confirm input.
Various data appears in the display. The manufacturer's code is also displayed.
-
Press -> button, wait until next display appears and press -> button again until "Select function xx" appears on display.
Indicated on display:
Rapid data transfer
HELP
Select function XX
NOTE:
-
The Login-procedure that follows is only required for VDO instrument clusters.
-
Motometer instrument clusters, continue.
-
Press button -1- twice.
-
Press -Q- button to confirm input.
Indicated on display:
Rapid data transfer
Q
11 - Login procedure