volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Fuel Delivery and Air Induction > < EGR Valve|Testing and Inspection
Page 1
background image

Thermal Vacuum Valve: Testing and Inspection

EGR Two-Way Valve, Checking

Test conditions

-

Engine oil temperature 50 °C minimum

Test sequence

-

Switch on ignition

-

Disconnect vacuum hose -5- from EGR two-way valve -1- N161

-

Disconnect vacuum hose -3- from EGR two-way valve and blow into hose
-

The EGR two way valve must allow air to pass to the vacuum pump connection (flow not blocked)

-

Disconnect 2 pin harness connector -2- from EGR two-way valve -1-

-

Blow again into vacuum hose -3-
-

The vacuum connection to the vacuum pump must be closed and the outlet to the outside -arrow- open

Fuel Delivery and Air Induction > < EGR Valve|Testing and Inspection